Experience multiple benefits when choosing our grease duct access panels from acudor and elmdor.
Grease duct access doors code.
Grease duct cleanouts and openings shall comply with all of the following.
Grease duct access doors.
To provide easy access into high temperature air ducts and grease duct systems.
Sandwich access door for grease duct or high.
The primary impact the code changes may have on grease duct selection is cost differentiation.
A 1 1 1 these requirements include but are not limited to all manner of cooking equipment exhaust hoods grease removal devices exhaust ductwork exhaust fans dampers fire extinguishing equipment and all other auxiliary or ancillary components or systems that are involved in the capture containment and control of grease laden cooking.
7 4 1 3 openings on horizontal grease duct systems shall be provided with safe access and a work platform when not easily accessible from a 3 m 10 ft stepladder.
To provide easy access into grease duct.
Our grease duct access panel from acudor is available in standard sizes 7 x 7 7 x 12 7 x 20 12 x 12 12 x 20 16 x 20 and 20 x 20.
Cleanouts and openings shall be equipped with tight fitting doors constructed of.
A huge benefit of these doors is that removing them is just as easy.
The right access panel should be installed in order to allow service personnel safe and convenient entry to these ducts.
The cleanliness of your ductwork system is highly dependent on the access that your kitchen exhaust cleaning professional has to it.
F2 grease duct sandwich access door.
7 4 1 4 support systems for horizontal grease duct systems 609 mm 24 in and larger in any cross sectional dimension shall be designed for the weight of the ductwork plus 363 kg.
Once you have the grease duct access doors in place and fitted firmly these will prevent any grease from dripping or leaking out.
This door was designed for applications requiring ul 1978 listing.
Access door application approval resides with the authority having jurisdiction.
Its ceramic fiber gasket allows its use with temperatures up to 2300 f.
Grease ducts shall not have openings except where required for the operation and maintenance of the system.
Best access doors recommends the ba gdd grease duct access doors that are perfect for application in commercial kitchen exhaust systems.
To prevent grease build up which can be a fire hazard access to grease ducts is necessary.
On site welded grease ducts must be wrapped in two layers of insulation tested to ul 2221 standards at the construction site ul 2221 classifi ed prefabricated stainless steel grease ducts no longer have to be contained in a fi re rated shaft.
The f2 grease duct sandwich access door is for grease duct applications and meets nfpa 96 standards.
If you have a different exhaust system installed at some point you can reinstall the same doors and enjoy the same benefits.